Technical Data
Test Flow Rate: | 0–25 L/min |
Oil Pump Flow Rate: | 40 L/min |
Temperature Control Range: | room temperature to +100 °C |
Power Supply Voltage: | 220 V / 50 Hz |
Machine Weight: | 300 kg |
Overall Dimension (L × W × H): | 1000 × 600 × 1560 mm |
Main Features
- The bypass valve circuit and the double adjustment system are used to adjust the flow rate and pressure of the test.
- A high-precision turbine flowmeter is used to measure the flow rate.
- A precision pressure gauge was used to measure the pressure.
- The test method meets the criteria: SAE HS806, ISO4548, etc.
Applications
This machine can be used to measure the flow characteristics, passage, sealing, opening pressure and reset performance of the filter.